How to Calculate the Cooling Capacity of a Data...
September 11, 2025

How to Calculate the Cooling Capacity of a Data Center Air Conditioning System

How to Accurately Calculate the Cooling Capacity Required for a Computer Room In today's rapidly advancing technological landscape, computer rooms have become essential spaces housing various IT equipment and data storage. To ensure that this equipment operates in an optimal environment, the temperature, humidity, and air quality of the computer...

Causes of Frost Buildup on Data Center Air Cond...
April 15, 2026

Causes of Frost Buildup on Data Center Air Conditioning Compressors and Solutions

The compressor is one of the most critical components in a constant temperature/humidity (precision) air conditioner. If the compressor fails, the entire cooling system stops working. Among common compressor issues — unusual noises, frost buildup, not starting — compressor frosting is one we see frequently. Below, we explain why it hap...

What factors affect the reliability of UPS batt...
September 11, 2025

What factors affect the reliability of UPS batteries?

Factors Affecting the Reliability of UPS Batteries For users, the purpose of purchasing a UPS uninterruptible power supply is to achieve more stable and efficient operation of electrical power. Therefore, any UPS power supply must have stability. The batteries used in UPS uninterruptible power supplies are lead-acid batteries. They operate on th...

Knowledge Hub

Analysis of Reasons Why Fans in Precision Air C...
April 15, 2026

Analysis of Reasons Why Fans in Precision Air Conditioning Units in Data Centers Fail to Operate

Why Precision Air Conditioner Fans Stop Working – Causes & Fixes The internal fan of a precision air conditioner plays a critical role in driving air circulation. In data center and server room environments, where precision cooling is essential, the fan operates continuously. Because it is a high-duty moving component, it is naturally more p...

Advantages of Laboratory Air Conditioning Over ...
April 14, 2026

Advantages of Laboratory Air Conditioning Over Comfort Air Conditioning in Laboratory Settings

Constant temperature and humidity air conditioners (also known as precision air conditioners) are designed for high airflow and variable heat loads. But how are they different from standard comfort air conditioners? Let’s break it down. Precision air conditioners (like the BetterPac series) are widely used in labs, workshops, and precision manuf...

Why is it necessary to drain the condensate fro...
April 14, 2026

Why is it necessary to drain the condensate from precision air conditioners?

The purpose of cleaning contaminants from a refrigeration system’s piping is to remove dirt, debris, and other foreign matter before they can enter the compressor or expansion valve. If contaminants reach the compressor, they can cause cylinder scoring and poor valve sealing, which affects normal operation. If they enter the expansion valve, the...

Today's Picks

Unfortunately, the information you searched was not found

sEARCH POST

Popular TAG

Popular product

VH-UR11 1–10 kVA UPS (Uninterruptible Power Sup...
VH-UR31 Uninterruptible Power Supply (UPS)
Embedded Environmental Monitoring Host – ...Embedded Environmental Monitoring Host – VH3300-II Series

Embedded Environmental Monitoring Host – VH3300-II Series

Architecture
ARM architecture, multi-language B/S design, built-in Linux operating system; no need to install additional servers or software
Water Leak Alarm
Built-in leak detection, plus a leak detection cord or sensor unit
4G module
Built-in 4G module, supports SMS and voice alerts (optional)
RPM
Internal Fan Speed Monitoring
Computer case
1U/19-inch standard chassis, compact design, suitable for various racks and enclosures
Standard
Industrial-grade design, stable 24/7 operation
Voltage
Wide input voltage range: 100–240 V AC
Design
Redundant Power Supply Design
Stable
Built-in independent watchdog system ensures zero downtime
Expand
Supports the expansion of distributed monitoring devices
Interface
Easy-to-use configuration software; front-panel ports for convenient wiring
More parameters
All-in-one cabinet monitoring
Single-row micro-module

Single-row micro-module

Rack-to-rack connectors
Comes standard with cabinet-mounting accessories for easy installation
L-shaped rail
A pair of trackless devices used together
1U blank panel
Used to separate hot and cold airflow within the cabinet, preventing airflow disruption; 1U tool-free installation
Fixed shelf
Designed to hold IT equipment, suitable for use in N-series server cabinets and blower cabinets with a depth of 1200 mm; load capacity: 100 kg
Cable management channel
Installs directly into the mounting holes on the U-post and is used to route horizontal cables; designed for use with switches
Vertical Cable Management Panel
Suitable for use with all cabinets, including cable management panels and PDU installation
Top-mounted cable tray
H-shaped cable trays can be categorized into power, low-voltage, and fiber-optic types
Row-to-row routing ladder
A cross-over used for inter-row routing
Cabinet base
Standard height: 300
Single-flap canopy module
Flip-up all-glass skylight with 95% light transmission; features a built-in lighting module, eliminating the need for additional lighting fixtures; designed to fit a 600mm-wide cabinet
Side doors and side doors with top trim
Cover the glass door and install a large screen to enhance the aesthetic appeal
UPS Module Unit
90–300 kVA main units come standard with a 30 kVA module
PDU
10+4, 16+4, 20+4
More parameters
Precision Air Conditioning for Data Centers
VH-UR33 Rack-Mounted UPS
VH-UT31 Uninterruptible Power Supply (UPS)
VH5030 Series Dust Detectors
VH-UT11 1–10 kVA UPS (Uninterruptible Power Sup...VH-UT11 1–10 kVA UPS (Uninterruptible Power Supply)

VH-UT11 1–10 kVA UPS (Uninterruptible Power Supply)

Equipment Type
DUninterruptible Power SuUPSTower-typeRack-mounted
Model (Rack-Mounted)
VH-UR1101(S)/VH-UR1102(S)/VH-UR1103(S)/VH-UR1106/VH-UR1110
Model (Tower Type)
VH-UT1101(S)/VH-UT1102(S)/VH-UT1103(S)/VH-UT1106(S)/VH-UT1110(S)
PF
1.0
DC voltage
36 VDC (standard model: 24 VDC)/72 VDC (standard model: 48 VDC)/96 VDC (standard model: 72 VDC)/192–240 Vdc (adjustable from 16 to 20 cells)
Charging current
Main unit: Default 5A (supports up to 12A) Standard unit: 1A
Auto-start on incoming call
Support
More parameters