Search productSearch post

Company Blog

Today's Picks

Unfortunately, the information you searched was not found

sEARCH POST

Popular TAG

Popular product

VH-UT11 1–10 kVA UPS (Uninterruptible Power Sup...VH-UT11 1–10 kVA UPS (Uninterruptible Power Supply)

VH-UT11 1–10 kVA UPS (Uninterruptible Power Supply)

Equipment Type
DUninterruptible Power SuUPSTower-typeRack-mounted
Model (Rack-Mounted)
VH-UR1101(S)/VH-UR1102(S)/VH-UR1103(S)/VH-UR1106/VH-UR1110
Model (Tower Type)
VH-UT1101(S)/VH-UT1102(S)/VH-UT1103(S)/VH-UT1106(S)/VH-UT1110(S)
PF
1.0
DC voltage
36 VDC (standard model: 24 VDC)/72 VDC (standard model: 48 VDC)/96 VDC (standard model: 72 VDC)/192–240 Vdc (adjustable from 16 to 20 cells)
Charging current
Main unit: Default 5A (supports up to 12A) Standard unit: 1A
Auto-start on incoming call
Support
More parameters
VH-UR31 Uninterruptible Power Supply (UPS)
VH5030 Series Dust Detectors
Embedded Environmental Monitoring Host – ...Embedded Environmental Monitoring Host – VH3300-II Series

Embedded Environmental Monitoring Host – VH3300-II Series

Architecture
ARM architecture, multi-language B/S design, built-in Linux operating system; no need to install additional servers or software
Water Leak Alarm
Built-in leak detection, plus a leak detection cord or sensor unit
4G module
Built-in 4G module, supports SMS and voice alerts (optional)
RPM
Internal Fan Speed Monitoring
Computer case
1U/19-inch standard chassis, compact design, suitable for various racks and enclosures
Standard
Industrial-grade design, stable 24/7 operation
Voltage
Wide input voltage range: 100–240 V AC
Design
Redundant Power Supply Design
Stable
Built-in independent watchdog system ensures zero downtime
Expand
Supports the expansion of distributed monitoring devices
Interface
Easy-to-use configuration software; front-panel ports for convenient wiring
More parameters
Single-row micro-module

Single-row micro-module

Rack-to-rack connectors
Comes standard with cabinet-mounting accessories for easy installation
L-shaped rail
A pair of trackless devices used together
1U blank panel
Used to separate hot and cold airflow within the cabinet, preventing airflow disruption; 1U tool-free installation
Fixed shelf
Designed to hold IT equipment, suitable for use in N-series server cabinets and blower cabinets with a depth of 1200 mm; load capacity: 100 kg
Cable management channel
Installs directly into the mounting holes on the U-post and is used to route horizontal cables; designed for use with switches
Vertical Cable Management Panel
Suitable for use with all cabinets, including cable management panels and PDU installation
Top-mounted cable tray
H-shaped cable trays can be categorized into power, low-voltage, and fiber-optic types
Row-to-row routing ladder
A cross-over used for inter-row routing
Cabinet base
Standard height: 300
Single-flap canopy module
Flip-up all-glass skylight with 95% light transmission; features a built-in lighting module, eliminating the need for additional lighting fixtures; designed to fit a 600mm-wide cabinet
Side doors and side doors with top trim
Cover the glass door and install a large screen to enhance the aesthetic appeal
UPS Module Unit
90–300 kVA main units come standard with a 30 kVA module
PDU
10+4, 16+4, 20+4
More parameters
All-in-one cabinet monitoring
VH-UR33 Rack-Mounted UPS
Dual-row micro-module
Smoke Sensor VH-602PC-4Smoke Sensor VH-602PC-4

Smoke Sensor VH-602PC-4

Operating voltage
9V–35V DC
Standby current
12 mA (relay normally closed) & 500 μA (relay normally open)
Trip current
Infrared LED is always on
sensor
Infrared photoelectric sensor
Operating temperature
-10°C to +50°C
Operating humidity
Up to 95% RH (non-condensing)
Resistance to RF interference
10MHz-1GHz 20V/m
Alarm Output
Normally open or normally closed (selectable); contact rating: 28 V DC, 100 mA
Reset method
Automatic reset or power-off reset (optional)
Coverage Area
When the ceiling height is between 6 and 12 meters, the coverage area of a single detector is 80 square meters for a typical protected area; when the ceiling height is less than 6 meters, the coverage area is 60 square meters. Specific parameters should be determined in accordance with the Design Code for Automatic Fire Alarm Systems (GD50116-98).
Applicable Standards
GB 4716-2005, EN 54-7
Sensitivity
0.5 dB/m (±0.1 dB/m)
Dimensions
104 mm (diameter) × 51 mm (height)
More parameters
Precision Air Conditioning for Data Centers
What's New

More contact information

No products in the cart.